Temperature
The measuring transducer records the temperature via a connected Pt1000 sensor and coverts the value into a standardized analogue output signal in the range between 010V/420 mA. 24 measuring range
| Veris CW2 Series | Analog Air Quality Sensor
SENSOR, CO2, WALL, TEMP TRANSMITTER, VOC, BACNET/MODBUS: INFO: : : ADD ALL TO CART . Accessories. No accessories found. Features Microprocessor based; Selfcalibrating; Dualbeam NDIR CO2 sensor; Easy to install; Field selectable; Multisensor platform Specifications. Input Power: Class 2; 20 to 30 Vdc, 24 VAC, 5060 Hz. Analog Output: Selectable 4 to 20 mA, 0 to …
VOC ROOM SENSOR SERIES | BAPI | HVAC Sensors | Gas Sensors ...
Product Description: Sensor, Air Quality, VOC, Room, 010V Out, BA/BS3FVOC10H210G60L6102JC35LT . Gas Type. Volatile Organic Compounds, Carbon Dioxide. Application. Indoor. Input. 15~35 VDC. Output. 0~10 VDC, 0~10 kohms. Humidity Sensor. Yes. Humidity Range. 0 to 95% RH. Temperature Sensor . Yes. Temperature Range. 32~122 deg F. Display. LCD. RoHS Compliant. Yes. …
QPM21 Series Duct Air Quality Sensor, CO2 Only, 0 to 10V
Siemens QPM2100 QPM21 Series Duct Air Quality Sensor, CO2 Only, 0 to 10V The QPM21 series duct air quality sensors optimize room comfort by enabling demandcontrolled ventilation. The sensors can acquire: CO2 and volatile organic compound (VOC) concentrations, relative humidity, and temperature. The sensor evaluates the CO2/VOC concentrations and transforms it to a 0 to 10 Vdc …
Air Quality Room Sensors | alliancetechnology
Room Air Quality (VOC) Sensor Power Supply AC/DC 24V Output: 0...10V Measuring Range: 0... VOC Download Datasheet. Room Air Quality (CO2) Sensors GRW 1. Room Air Quality (C02) Sensor Power Supply AC/DC 24V Output: 0...10V Measuring Range: 0...2,000PPM (CO2) Download Datasheet. Room Flush mount Air Quality (CO2) Humidity Temperature Sensors CRF 5. . …
Air Quality Duct Sensors | alliancetechnology
Duct Air Quality (VOC) Sensor Power Supply AC/DC 24V Output: 0...10V Measuring Range: 0... VOC Immersion length 100mm 150mm. Download Datasheet. Air Quality (CO2) Duct Sensors GDI 1. Duct Air Quality (C02) Sensor Power Supply AC/DC 24V Output: 0...10V Measuring Range: 0...2,000PPM (CO2) Immersion length 150mm Download Datasheet. Air Quality (CO) Duct Sensors …
VOC Sensor, BAPIStat “Quantum Prime”
Display, 10K3 Thermistor Temp Sensor, Slider Temp Setpoint, 0 to 10V Setpoint Output, 10 to 32 °C Setpoint Range, ±2%RH Accuracy, 0 to RH Range, 0 to 10V %RH Output, 0 to 10V VOC Output (0 to 2,000 ppm CO2 Equivalent Range), Occupant Override, Common Ground Configuration BA/BQP60CBVB1C10J .... BAPIStat “Quantum Prime” VOC/Temp/Humidity Sensor with Display, 10K4 …
AirSens Intelligent IAQ sensors Soler Palau
Airsens VOC: This versatile version reacts to sporadic changes to the accumulation of substancederived odours; Volatile Organic Compounds such as alcohols, aldehydes, ketones and organic acids. AirSens RH : Sensor that recognizes the relative humidity inside an area, therefore, recommended for places where this is variable or tends to be concentrated excessively.
Sensors Home | Belimo
3 Sensors The perfect complement to actuators and valves Application Sensor types Duct / Air Pressure sensor range 4 Duct sensors and duct humidistat 5
0 To 10V Active Temperature Sensors | Wireless Sensors ...
TER Active Room Temperature Sensor, 010V Outputs . Active room temperature transmitter. 3 x 010Vdc output signals. Can be used as a controller as well. Large range of options. Wall Mounted. 24Vac/dc power supply. Active Room Temperature Sensor, 010V Outputs Details. Datasheet (650kB) £ £ inc VAT TEKLU Duct Air Temperature Transmitter, 0..10V . Duct air temperature …
Gesamtindex nach Blattnummern rinck electronics
16x R, Sensor: 16x 10V: C915: /… 4 Kanal Messverstärker für Messbückeneingang (Weatstonebrücke) MODBUS CANBUS: 4x +100mV (5V) BUS: C920: : Programmierbarer Logikbaustein : 16x DC digital: 16x digital / Schliesser: C930: : Programmierbarer Relaisbaustein: 16x 24V DC digital: 16x Schliesser: C940: : Jalousie Auf Zu Steuermodul 6 …
Siemens QPA2002 SENSOR, CO2 VOC, ROOM, 010V, SENSING
Siemens QPA2002 SENSOR, CO2 VOC, ROOM, 010V, SENSING
KTMCO2SDU, CO² og tempsensor for kanal, 010V ...
KTMCO2SDU, CO² og tempsensor for kanal, 010V Multirange. Logg inn for pris og bestilling. 150181121001200. Logg inn for bestilling og priser. Dersom du ikke har konto kan du registrere kundeavtale: KLIKK HER! Varenummer: 1438985 Kategori: Luftstrøm og kvalitet. Produktark/FDV engelsk. Katalogside engelsk. Leveradørens varenummer: 150181121001200. Leverandør: S+S …
QPA2002 Room CO2/VOC Sensor, 010V / 420mA Output ...
QPA2002 Room CO2/VOC Sensor, 010V / 420mA Output (Selectable) QPA2002 Room CO2/VOC Sensor, 010V / 420mA Output (Selectable) The store will not …
QPA2002D Room CO2/VOC Sensor, 010V / 420mA Output ...
QPA2002D Room CO2/VOC Sensor, 010V / 420mA Output (Selectable), with Display QPA2002D Room CO2/VOC Sensor, 010V / 420mA Output (Selectable), with Display The store will not work correctly in the case when cookies are disabled.
VOC føler til kanal med relæ og 010V / 420mA udgang ...
VOC føler til kanal med relæ og 010V / 420mA udgang. VOC føler til kanal med relæ og 010V / 420mA udgang Email til en ven. Tilgængelighed: Bestilles fra producent, tages ikke retur. Varenummer: KLQW. Producentens varenr.: 150131507301500. GTIN/ISBN/EAN: 4251325624297. Leveringstid: ca. 12 uger. Listepris: DKK 1821,71 inkl. moms Din pris: DKK 1366,28 inkl. moms Antal: Bestil ...
User manual for sensor ADSCO224 Air quality sensors
0 – 10V analog output + output relay doesn’t need maintenance during operation long service life and stability Description: It is a carbon dioxide (CO 2) room sensor with an 010V analog output. The output voltage is proportional to the concentration of CO 2. The measuring of CO 2 works on the principle of infrared radiation attenuation dependence on the CO 2 concentration in the air ...
Measurement Reading to 010V Signal Converter
This tool uses the following formula to calculate the output over a 010V scale from a specified measurement input reading and range: Linear V out = 10 x ((Rdg – Low Limit) / (High Limit – Low Limit)) Parameters Measurement Unit. Enter the measurement unit symbol or description for the input value and range specified. Measurement Reading . Add the measurement parameter value in the ...
S+S Regeltechnik: PM, VOC and CO2 sensors
room sensor for humidity, temperature, fine dust (PM), air quality (VOC) and CO2AER ASGARD® RFTMPSLQCO2 Modbus. Multifunctional room sensor and measuring transducer for humidity, temperature, air quality (VOC), fine dust (PM) and CO2 content, calibratable, with Modbus connection. CO 2: 0..2000 ppm (default), 0..5000 ppm.
Buy DPDQ402000 Carel Duct mounting CO2 sensor with a 0 ...
DPDQ402000 Duct mounting CO2 sensor with a 0 to 10 Vdc output Carel Duct mounting CO2 Air quality sensor with a 0..10V output . APPLICATION: The selfcalibrating microprocessorcontrolled CO2 and mixed gas measuring device is used for the detection of air quality and ⁄ or CO2 content in air within a range of 0 ppm to 2000 ppm CO2. Measuring signals are converted into standard signals of 0 ...
ACI | Q5GENL100LOXVOC | Smart Sensor, VOC''s, 0 ...
Smart Sensor, VOC''s, 0 LEL, 3 SPDT Relays, NEMA 4X, 420mA, 210V, or Modbus RTU
010 Volts Output Hydrostatic Sensors, Probes Transducers
150m freshwater submersible pressure sensor with 10v output. Freshwater mH2O gauge range 010V out submersible level sensor. mH2O range 010V signal submersible diesel level sensor. BMS water tank 6mH2Og range 010V out submersible level sensor. 30 ft high hygienic tank level transducer with 0 to 10 volt output for use with lubricants.
Air Quality Transmitter – Sense Control Technologies
• Maintenance free compact MEMS type MOX sensor • VOC (Volatile Organic Compounds): Ethanol, Methane, Carbon Monoxide, Hydrogen, Ammonia • VOC ranges, Low, Medium, High • VOC output signal 420 mA and 0…10 Vdc • Easy field calibration • Operating voltage 24V AC/DC. Applications • Air quality applications: measuring VOC concentrations as of odors; tobacco smoke, body odor, or ...
Specification Sheet | SpaceLogic ...
VOC Sensor Sensor type Solid state Output range 0 to AQI for VOC Accuracy ±15% of measured value Output scale 0 to 1,000 ppb of total VOC (TVOC) AQI table* Level Ventilation Recommendation TVOC (ppb) >61% Greatly increased >610 20 to 61% Significantly increased 200 to 610 10 to 20% Slightly increased 100 to 200 5 to 10% Average 50 to 100 0 to 5% Target value 0 to 50 RH Sensor …
QPA63 Series
2 sensor and a VOC 1 sensor with a heated stannic dioxide semiconductor. Operating voltage: 24 Vac Output signals: 0 to 10 Vdc The QPA63 VOC Sensor can detect any of the following gases: Alcohol Ethylene Oxide nHexane 2 Acetone Formaldehyde nPatene Acrylonitriles Hydrogen Propane Ammonia Hydrogen Sulfide R11 Benzene Isobutane R12 Carbon Dioxide Methane R123 Carbon Monoxide …
Specification Sheet | SpaceLogic ...
• VOC sensor available • Temperature output on all models • 61 mm (”) backlit color touchscreen and LCD, three button display options available Digital temperature indication (° display resolution of °F or °C Digital humidity indication (% RH display resolution) Digital CO 2 indication (0 to 2000 ppm display resolution) Selectable temp, RH and fan speed setpoint (0 ...
VOC føler til kanal, 010V udgang.
VOC føler til kanal, 010V udgang. VOC føler til kanal, 010V udgang Email til en ven. Tilgængelighed: Bestilles fra producent, tages ikke retur. Varenummer: KLQSDU. Producentens varenr.: 150131701001500. GTIN/ISBN/EAN: 4251325624280. Leveringstid: 25 hverdage. Listepris: DKK 1745,16 inkl. moms Din pris: DKK 1308,87 inkl. moms Antal: Bestil. Beskrivelse; Specifikationer ...